Nitrogen in flue gas and in fuel is combined with Oxygen in a furnace at the high temperature so that NOx is created. Among those, NO and NO2 affect plants, animals and humans like as SOx. The amount of NOx have to be controlled by the following facilities. Selective Catalytic Reduction system and Selective Non-Catalytic Reduction system are used for removing NOx.
SCR Process (Selective Catalytic Reduction System)
 
SCR Process
NOx contacts with reductants such as ammonia or urea and react with those on the catalyst surface. Through this chemical process, NOx divides into N2 nad H2O and even organic matters(CxHy: Dioxins and Furans) are oxidized and removed. SCR Process is used for both De-NOx and De-Dioxin.

Catalyst
Ammonia Injection System
SNCR Process (Selective Non-Catalytic Reduction System)
 
SNCR Process
NOx is deoxidized by a reductant such as Urea without catalyst in the temperature rage of 800 ~ 900℃ (normally over 700 ℃) and is finally changed into N2 gas.
Applicable Field
Industrial and Municipal Waste Incinerator, Power Plant, Chemical Plant(Nitric Acid), Iron Plant
 